LEO(II) Lyse Solution, produced by Labnovation company, is an advanced, calibrated hemolyzing reagent supplied and offered by Arya Tashkhis Pars in Iran. Read more
- دستگاه سازگار: Dymind DH-73, DH-76, DF-55
- حجم: 1 لیتر
- برند مبدا: Labnovation
- برند واردکننده: آریا تشخیص پارس
100% original
Guarantee of the originality of the product
Payment methods
You can pay for the product in the usual ways
10 days money back guarantee
If you are not satisfied with the product, you can receive your money within ten days after purchase
Please buy for advice LEO(II) Lyse Solution Call the numbers below
List of files related to LEO(II) Lyse Solution
Introduction LEO(II) Lyse Solution
LEO(II) Lyse Solution, produced by the specialized Labnovation company, is an advanced, calibrated hemolyzing reagent supplied and offered across laboratory markets by Arya Tashkhis Pars.
Introduction to Labnovation LEO(II) Lyse Solution
Achieving ideal scattergram patterns and precise leukocyte differentiation in 5-part differential auto analyzers depends heavily on hemolysis timing and the target cell membrane stability. LEO(II) Lyse Solution, produced by the specialized Labnovation company, is an advanced, calibrated hemolyzing reagent supplied and offered across laboratory markets by Arya Tashkhis Pars. Formulated in a practical 1-liter volume, this reagent is specifically designed for operation in advanced platforms such as the Dymind DH-73, DH-76, and Dymind DF-55, methodically breaking down erythrocytes to clear the path for accurate leukocyte and hemoglobin concentration measurements.
Strategic Applications of LEO II Lyse Solution in 5-Part Systems
This sensitive biochemical reagent plays key roles within the complete blood count (CBC) testing protocol:
Rapid and Complete Red Blood Cell Destruction: Disruption of RBC membranes in a fraction of a second prevents signal overlap with target cells in the counting channel.
Preparing Leukocytes for Scattergram Analysis: Preserves the precise physical dimensions and granularity characteristics of white blood cells (WBCs) to enable 5-part differential differentiation on advanced optical scattergrams.
Stabilizing Hemoglobin Complexes: Releases RBC-bound hemoglobin and converts it into a stable color complex for accurate photometric concentration readings at specific wavelengths.
Reducing Systematic Diagnostic Errors: Enhances the system's diagnostic accuracy in differentiating eosinophils, basophils, neutrophils, lymphocytes, and monocytes in pathological samples.
Technical Specifications and Systemic Compatibility
| Product Technical Specs | Details and Operational Requirements |
|---|---|
| Brand Name & Specific Code | LEO(II) Lyse Solution - Dymind Lyse |
| Product Nature & Type | Laboratory Solutions (Specialized Hemolyzer) |
| Laboratory Department | Hematology Solutions |
| Target Device Platform | Dymind Hematology Solutions |
| Compatible Analyzers | Dymind DH-73 / DH-76 / DF-55 |
| Packaging Configuration | Durable 1-Liter Bottle |
| Manufacturer / Importer | Labnovation / Arya Tashkhis Pars |
Operational Benefits and Quality Features of LEO(II) Solution
Full Compatibility with Dymind Needles and Lines: Calibrated according to the aspiration patterns and hydraulic viscosity of Dymind platforms to prevent clogging or precipitation within delicate internal lines.
High Long-Term Storage Stability: Features a stabilized formulation that maintains lysing power and quality down to the last drop.
No Manual Preparation Required (Ready-to-Use): Direct bottle connection to the instrument eliminates dilution procedures, reducing human error and cross-contamination risks to zero.
Technical Limitations and Storage Protocols
To prevent shifts in leukocyte clustering, laboratory personnel must strictly adhere to the following factors:
Strict Temperature and UV Control: Store this reagent between 2 and 30°C. Freezing conditions or direct exposure to sunlight degrade active hemolyzing compounds, causing "incomplete lysis" and false error responses in platelet and white blood cell counts.
Preventing Air Ingress and Oxidation: Leaving the container cap open alters the solution's chemical properties. Ensure instrument connectors fit tightly on the 1-liter bottle.
Operator Protection: Due to active cell-lysing compounds, avoid direct contact with skin and eyes, and perform container changeovers in a well-ventilated area.
Price Inquiry and Purchasing Labnovation LEO(II) Lyse Solution
Ensuring scattergram data accuracy on Dymind 5-part analyzers relies heavily on the authenticity and biochemical consistency of the lysing reagent. To buy LEO(II) Lyse Solution in a 1-liter volume and inquire about dedicated Dymind hematology kit pricing, visit the Padina Vista portal or contact our sales specialists. This product is supplied with guaranteed authenticity, valid expiration dates, and official authorization from Arya Tashkhis Pars.
Technical Specifications محلول لایز LEO(II)
| Brand | Dymind |
| Model | LEO(II) Lyse Solution |
| نام شرکت |
شرکت سیما پلیمر آریا |
English
فارسی
English
العربية